Validation result

Information

File Name
22170ce7-63f9-465a-bc8f-25bb07c722c4.86cba035-ead5-4a15-96e2-232e909b44d8.sr.detections.dcm
OID :
1.3.6.1.4.1.12559.11.11.4.33507
Validation Date :
11/26/25 11:05:58 AM (CET GMT+0100)
PixelMed (Wed Dec 18 15:38:40 EST 2019)
DICOM SR Conformance (Wed Dec 18 15:38:40 EST 2019)
Validation Results :
DONE_PASSED
Permanent link :
https://connectathon.ihe-catalyst.net/evs/report.seam?oid=1.3.6.1.4.1.12559.11.11.4.33507
Data Visibility :
Public

Validation Results

«
»

PixelMed Standard Report
XML

«
»
Validation Summary
8
4

DICOM SR ConformancePASSED

Validation Summary
8
4
Constraint Description
Warning: 1.2: /CONTAINER (126000,DCM,"Imaging Measurement Report")/UIDREF (121012,DCM,"Device Observer UID"): Content Item not in template
Constraint Description
Warning: 1.5: /CONTAINER (126000,DCM,"Imaging Measurement Report")/CONTAINER (126000,DCM,"Imaging measurement report"): Content Item not in template
Constraint Description
Warning: 1.5.1: /CONTAINER (126000,DCM,"Imaging Measurement Report")/CONTAINER (126000,DCM,"Imaging measurement report")/TEXT (111001,DCM,"Algorithm Name"): Content Item not in template
Constraint Description
Warning: 1.5.2: /CONTAINER (126000,DCM,"Imaging Measurement Report")/CONTAINER (126000,DCM,"Imaging measurement report")/TEXT (111003,DCM,"Algorithm Version"): Content Item not in template
Constraint Description
Warning: 1.6.1.3: /CONTAINER (126000,DCM,"Imaging Measurement Report")/CONTAINER (126010,DCM,"Imaging Measurements")/CONTAINER (125007,DCM,"Measurement Group")/CODE (373572006,SCT,"Clinical finding absent"): Content Item not in template
Constraint Description
Warning: 1.6.1.4: /CONTAINER (126000,DCM,"Imaging Measurement Report")/CONTAINER (126010,DCM,"Imaging Measurements")/CONTAINER (125007,DCM,"Measurement Group")/IMAGE (260753009,SCT,"Source"): Content Item not in template
Constraint Description
Warning: 1.6.2.3: /CONTAINER (126000,DCM,"Imaging Measurement Report")/CONTAINER (126010,DCM,"Imaging Measurements")/CONTAINER (125007,DCM,"Measurement Group")/CODE (373572006,SCT,"Clinical finding absent"): Content Item not in template
Constraint Description
Warning: 1.6.2.4: /CONTAINER (126000,DCM,"Imaging Measurement Report")/CONTAINER (126010,DCM,"Imaging Measurements")/CONTAINER (125007,DCM,"Measurement Group")/IMAGE (260753009,SCT,"Source"): Content Item not in template
Constraint Description
Found Comprehensive3DSR IOD
Constraint Description
Found Root Template TID_1500 (MeasurementReport)
Constraint Description
Root Template Validation Complete
Constraint Description
IOD validation complete

File Content



Metadata
Metadata (XML)
Metadata (Tree)
Binary content

«
»

Unable to prettify DICOM: Null charset name
1