Search Criteria : 25 assertions found for this search Review filtered assertions

Assertion

Applies to

Applied to
Not applied to

Coverage

Covered by
Not covered by
Id scheme
Assertion id
Status
Testable?
#Coverage
#Applies to
Comment
Predicate
Page
Tags
Last changed
Actions
RAD129RAD129-001to be reviewedTestable 0 1 SimulatorQuery Objects Request : The Requester shall support making requests to more than one Responder38Section 4.129.4.17/22/21 2:11:39 PM by Clément Lagorce
RAD129RAD129-002to be reviewedTestable 0 1 SimulatorQuery Objects Request : The Responder shall support handling request from more than one Requester38Section 4.129.4.17/22/21 2:11:53 PM by Clément Lagorce
RAD129RAD129-003to be reviewedTestable 0 1 SimulatorQuery Objects Request : The Query Objects Request message is a Search transaction of the DICOM Studies Service. See DICOM PS3.18 Section 10.6.38Section 4.129.4.1.29/23/21 9:23:25 AM by Clément Lagorce
RAD129RAD129-004to be reviewedTestable 0 1 Conformance checkerQuery Objects Request : The Requester shall issue the Query Objects Request using the QIDO-RS Query endpointprovided by the Responder38Section 4.129.4.1.27/22/21 2:12:14 PM by Clément Lagorce
RAD129RAD129-005to be reviewedTestable 0 1 Conformance checkerQuery Objects Request :The message shall correspond to one of the Target Resources listed in Table 4.129.4.1.2-1.38Section 4.129.4.1.29/23/21 9:24:28 AM by Clément Lagorce
RAD129RAD129-006to be reviewedTestable 0 2 SimulatorQuery Objects Request : The only binding required for both the Requester and Responder is HTTP-GET.38Section 4.129.4.1.27/22/21 2:12:35 PM by Clément Lagorce
RAD129RAD129-007to be reviewedTestable 0 1 Conformance checkerQuery Objects Request : The request shall include the header parameters defined in Table 4.129.4.1.2-3 to indicate themedia type of the response.39Section 4.129.4.1.27/22/21 2:12:48 PM by Clément Lagorce
RAD129RAD129-008to be reviewedTestable 0 1 Conformance checker Query Objects Request : The Requester shall support all keys required for the SCU as defined in RAD TF-2: Table 4.14-1.39Section 4.129.4.1.27/22/21 2:12:56 PM by Clément Lagorce
RAD129RAD129-009to be reviewedTestable 0 1 Conformance checkerQuery Objects Request : In addition, the Requester shall be capable of using the following attributes as matching key and return key : Issuer of Patient ID (0010,0021) and Issuer of Accession Number Sequence (0008,0051)39Section 4.129.4.1.27/22/21 2:13:04 PM by Clément Lagorce
RAD129RAD129-010to be reviewedTestable 0 1 Conformance checkerQuery Objects Request : The Requester may implement one or more of the sets of matching listed in table 4.129.1.2-4 or return keys for the Query SCU40Section 4.129.4.1.27/22/21 2:13:12 PM by Clément Lagorce
RAD129RAD129-011to be reviewedTestable 0 1 SimulatorQuery Objects Request : The Requester shall issue the Query Objects Request using the endpoint designated by the Responder for the XDS-I Backend Option.40Section 4.129.4.1.2.17/22/21 2:13:50 PM by Clément Lagorce
RAD129RAD129-012to be reviewedTestable 0 1 Conformance checkerQuery Objects Request : For Requesting Service Code Sequence (0032,1034) as a matching key, the Requester may usevalues from the DICOM Content Mapping Resource (DICOM PS3.16) Context Group CID 7030955 Institutional Departments, Units and Services.40Section 4.129.4.1.2.17/22/21 2:14:20 PM by Clément Lagorce
RAD129RAD129-013to be reviewedTestable 0 1 Conformance checkerQuery Objects Request :The Responder shall parse the request, perform the search indicated using the matching rules in DICOM PS3.18 Section 8.3.4, and return a response. 40Section 4.129.4.1.2.39/23/21 9:26:20 AM by Clément Lagorce
RAD129RAD129-014to be reviewedTestable 0 1 Conformance checkerQuery Objects Request : The Responder shall support all keys required for the SCP as defined in the sections referencedin Table 4.129.4.1.3-141Section 4.129.4.1.2.37/22/21 2:14:41 PM by Clément Lagorce
RAD129RAD129-015to be reviewedTestable 0 1 Conformance checkerQuery Objects Request : In addition, the Responder shall support Issuer of Patient ID (0010,0021) and Issuer of AccessionNumber Sequence (0008,0051) as both matching and return keys.41Section 4.129.4.1.2.37/22/21 2:14:50 PM by Clément Lagorce
RAD129RAD129-017to be reviewedTestable 0 1 SimulatorQuery Objects Request : A Responder executes the following general step : Receives the QIDO-RS query request, Maps the QIDO-RS query parameters into Registry Stored Query parameters, Receives the Registry Stored Query response, Maps the Registry Stored Query response into a QIDO-RS query response.41Section 4.129.4.1.3.17/22/21 2:16:34 PM by Clément Lagorce
RAD129RAD129-018to be reviewedTestable 0 1 Conformance checkerQuery Objects Request : The Responder shall support the Registry Stored Query [ITI-18] transaction as an XDS Document Consumer using the FindDocuments query in ITI TF-2: 3.18.4.1.2.3.7.1 and FindDocumentsByReferenceId query in ITI TF-2: 3.18.4.1.2.3.7.14. 41Section 4.129.4.1.3.19/23/21 9:28:19 AM by Clément Lagorce
RAD129RAD129-019to be reviewedTestable 0 1 Conformance checkerQuery Objects Request : The Responder may support other stored queries defined in [ITI-18].41Section 4.129.4.1.3.17/22/21 2:18:10 PM by Clément Lagorce
RAD129RAD129-020to be reviewedTestable 0 1 Conformance checkerQuery Objects Request :When populating QIDO-RS return keys using Document Sharing metadata, the Responder shall follow the requirements in RAD TF-2: 4.68.4.1.2.3.2 and 4.68.4.1.2.3.3.41Section 4.129.4.1.3.19/23/21 9:30:21 AM by Clément Lagorce
RAD129RAD129-021to be reviewedTestable 0 1 Conformance checkerQuery Objects Request : The following attributes have no direct correspondences in the Registry Stored Query but arerequired to be supported by Responder as matching keys. These attributes may be available in the XDS-I manifest or the instances referenced by the manifest : Patients Name (0010,0010), Referring Physicians Name (0008,0090), Study ID (0020,0010)41Section 4.129.4.1.3.17/22/21 2:19:11 PM by Clément Lagorce